Product Number: EJA210A-EMHA1F4B-97DN/CF1/T
Model: Flange Mounted Differential Pressure Transmitter
Manufacturer: Yokogawa
- Model: EJA210A Flange-mounted differential pressure transmitter
- Output signal: -E - 4 to 20 mA DC with digital communication (HART protocol, refer to GS 01C22T01-00EN)
- Measurement span (Capsule): M - 1 to 100 kPa {100 to 10000 mmH2O} {4 to 400 inH2O} {10 to 1000 mbar}
- High pressure side (Process flange side) wetted parts material: H- [Diaphragm] - Hastelloy C-276
- Process flange range: A1 - ANSI Class 150
- Process flange size/material: F - 3-inch (80 mm) / SUS316
- Low pressure side process connection: 4 - with 1/2NPT female process connector
- Bolts and nuts material: B - SUS630
- Installation: -9 - Horizontal impulse piping type, left side high pressure
- Electrical connection: 7 - 1/2 NPT female, two electrical connections and a blind plug
- Integral indicator: D - Digital indicator - N - Always N
Optional codes:
- /CF1 - Factory Mutual
Canadian Standards Association (CSA)
Applicable standard: C22.2 No. 0, No. 0.4, No. 25, No. 30, No. 94, No. 142
Certificate: 1089598
Explosionproof for Class I, Division 1, Groups B, C and D
Dustignitionproof for Class II/III, Division 1, Groups E, F and G
Division2 SEALS NOT REQUIRED , Temp. Class: T4, T5, T6 Encl Type 4x
Max. Process Temp.: T4; 120 C (248 F), T5; 100 C (212 F), T6; 85 C (185 F)
Amb. Temp.: 40 to 80 C ( 40 to 176 F)
Applicable standard: C22.2 No. 0, No. 0.4, No. 25, No. 30, No. 94, No. 142
Certificate: 1089598
Explosionproof for Class I, Division 1, Groups B, C and D
Dustignitionproof for Class II/III, Division 1, Groups E, F and G
Division2 SEALS NOT REQUIRED , Temp. Class: T4, T5, T6 Encl Type 4x
Max. Process Temp.: T4; 120 C (248 F), T5; 100 C (212 F), T6; 85 C (185 F)
Amb. Temp.: 40 to 80 C ( 40 to 176 F)
- /T - Teflon film
Diaphragm protection from sticky process fluid by FEP Teflon film attached with fluorinated oil
Operation range: 20 to 120 C, 0 to 2 MPa (Not applicable for vacuum service)
Operation range: 20 to 120 C, 0 to 2 MPa (Not applicable for vacuum service)
برچسب ها: یوکوگاوا,
پرشر ترانسمیتر,
ترانسمیتر فشار,
فلنج,
yokogawa,
pressure transmitter,
transmitter